供应


智能制造网供应网 6SL3210-1PE21-1UL0

6SL3210-1PE21-1UL0

  • 产地
  • 所在地
  • 南京
  • 广东广州市

更新时间:2021-02-12

有效日期:已过期

产品详情

 

 

产品 规格:【德国原装,全新*】
产品 质量:【*,假一罚十】
产品 价格:【薄利多销,行业zui低】
产品 货期:【库存销售,现买现卖】

 

:*

 

;    

: 

广州鸿懿电气设备有限公司竭诚为您服务

 

 

更多产品和报价咨询扫二维码加我

 

购物需知

1、西门子产品均为密封包装,外包装详见产品图片,白色标签上均有西门子品牌LOGO及产品订货号,各位买家在收到货后,请核对型号无误,再拆包装

 

2、本公司销售的产品一律为(原装**假一罚十*质保一年) 本公司签约正式的销售合同,开具17%的增值税发票、普通发票。

 

6SL3210-1PE21-1UL0 
西门子产品订货号:6SL32101PE211UL0

西门子产品价格:168  RMB

西门子产品净重:1.100 Kg

西门子产品承诺:质保一年,原装*

西门子产品尺寸:270.00 x 225.00 x 85.00

 

概述

SINAMICS G120C, frame sizes FSAA to FSF, with Inligent Operator Panel IOP

SINAMICS G120C compact inverters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.

SINAMICS G120C inverters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.

优势

  • Compact design
  • Side-by-side design
  • High power density, low envelope dimensions
  • Simple installation in the tightest space
  • Low space requirement
  • Use in small control cabinets, close to the machine
  • Optimized parameter set
  • Optimized commissioning
  • Getting Started document
  • BOP‑2 or IOP operator panels can be used
  • Integrated USB connection
  • Simple and fast software parameter assignment
  • Simple to use during commissioning and in operation
  • Minimized training costs, existing SINAMICS know-how can be used
  • High degree of service friendliness, simple maintenance
  • Plug-in terminals
  • Cloning function using BOP‑2, IOP or memory card
  • Operating hours counter for "drive on" and "motor on"
  • Fast mechanical installation
  • Intuitive standard commissioning
  • Component of Totally Integrated Automation
  • Energy-efficient, sensorless vector control
  • Automatic flux reduction with V/f ECO
  • Integrated energy saving computer
  • Safety Integrated (STO)
  • Communications versions with PROFINET / EtherNet/IP, PROFIBUS DP, USS/Modbus RTU
  • Coated modules
  • Operation up to an ambient temperature of 60 °C (140 °F)

设计

SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device.

The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).

SINAMICS G120C, frame size FSAA with BOP-2

SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediay connected to PROFIBUS and/or PROFINET fieldbus systems without parameterization.

SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs.

SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.

Line-side components

Line reactors

Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter.

Recommended line-side power components

Standard fuses can be used for the SINAMICS G120C. These must be dimensioned to comply with local regulations. In this chapter, you will find recommended components such as fuses and circuit breakers in compliance with IEC and UL regulations.

DC link components

Braking resistors

Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch).

Load-side power components

Output reactors

Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.

Supplementary system components

Inligent Operator Panel IOP

Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C.

Basic Operator Panel BOP-2

A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled.

Memory card

The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediay ready for use again. The associated memory card holder is integrated in the inverter.

PC inverter connection kit 2

For controlling and commissioning an inverter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC.

Spare parts

Shield plates

A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size of the SINAMICS G120C, and can also be ordered as spare parts.

Spare parts kit

This kit comprises four I/O terminals, one RS485 terminal, two pairs of Control Unit doors (1 × PN and 1 × other communication versions) and one blanking cover.

Set of connectors

A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the SINAMICS G120C inverter.

Roof-mounted fan

A roof-mounted fan (at the top of the device) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.

Fan unit

A replacement fan (at the rear of the device; heat sink) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.

集成

Connection example for SINAMICS G120C

 

USS/Modbus RTU communication interface

PROFIBUS DP communication interface

PROFINET, EtherNet/IP communication interface

 

6SL3210-1PE21-1UL0 
西门子产品订货号:6SL32101PE211UL0

西门子产品价格:168  RMB

西门子产品净重:1.100 Kg

西门子产品承诺:质保一年,原装*

西门子产品尺寸:270.00 x 225.00 x 85.00

 

 

 

Control Units

Power Modules degree of protection IP20

 

PM240‑2/PM240

PM250

CU230P‑2

✓ 

✓ 

CU240E‑2

✓ 

✓ 

CU250S‑2

✓ 

✓ 


 

 

PM240, PM240‑2 and PM250 Power Modules

Rated power 1)

 

Rated output current Irated2)

PM240‑2 Power Modules 3)
Degree of protection IP20

All CUs pluggable

PM250
Power Module degree of protection IP20

All CUs pluggable

kW

hp

A

Article No.

Article No.

200 ... 240 V 1 AC/3 AC

0.55

0.75

3.2

6SL3210-1PB13-0❒L0

0.75

1

4.2

6SL321❒-1PB13-8❒L0

1.1

1.5

6

6SL3210-1PB15-5❒L0

1.5

2

7.4

6SL3210-1PB17-4❒L0

2.2

3

10.4

6SL321❒-1PB21-0❒L0

3

4

13.6

6SL3210-1PB21-4❒L0

4

5

17.5

6SL321❒-1PB21-8❒L0

200 ... 240 V 3 AC

5.5

7.5

22

6SL3210-1PC22-2❒L0

7.5

10

28

6SL3210-1PC22-8❒L0

11

15

42

6SL3210-1PC24-2UL0

15

20

54

6SL3210-1PC25-4UL0

18.5

25

68

6SL3210-1PC26-8UL0

22

30

80

6SL3210-1*-0UL0

30

40

104

6SL3210-1PC31-1UL0

37

50

130

6SL3210-1PC31-3UL0

45

60

154

6SL3210-1PC31-6UL0

55

75

178

6SL3210-1PC31-8UL0

380 ... 480 V 3 AC

0.37 4)

0.5

1.3

4)

0.55

0.75

1.7

6SL3210-1PE11-8❒L1

0.75

1

2.2

6SL3210-1PE12-3❒L1

1.1

1.5

3.1

6SL3210-1PE13-2❒L1

1.5

2

4.1

6SL3210-1PE14-3❒L1

2.2

3

5.9

6SL3210-1PE16-1❒L1

3

4

7.7

6SL321❒-1PE18-0❒L1

4

5

10.2

6SL3210-1PE21-1❒L0

5.5

7.5

13.2

6SL3210-1PE21-4❒L0

7.5

10

18

6SL321❒-1PE21-8❒L0

6SL3225-0BE25-5AA1

11

15

26/25

6SL3210-1PE22-7❒L0

6SL3225-0BE27-5AA1

15

20

32

6SL321❒-1PE23-3❒L0

6SL3225-0BE31-1AA1

18.5

25

38

6SL3210-1PE23-8❒L0

6SL3225-0BE31-5❒A0

22

30

45

6SL3210-1PE24-5❒L0

6SL3225-0BE31-8❒A0

30

40

60

6SL3210-1PE26-0❒L0

6SL3225-0BE32-2❒A0

37

50

75

6SL3210-1PE27-5❒L0

6SL3225-0BE33-0❒A0

45

60

90

6SL3210-1PE28-8❒L0

6SL3225-0BE33-7❒A0

55

75

110

6SL3210-1PE31-1❒L0

6SL3225-0BE34-5❒A0

75

100

145

6SL3210-1PE31-5❒L0

6SL3225-0BE35-5❒A0

90

125

178

6SL3210-1PE31-8❒L0

6SL3225-0BE37-5❒A0

110

150

205

6SL3210-1PE32-1❒L0

132

200

250

6SL3210-1PE32-5❒L0

160 3)

250

302

6SL3224-0XE41-3UA0

200 3)

300

370

6SL3224-0XE41-6UA0

250 3)

400

477

6SL3224-0XE42-0UA0

500 ... 690 V 3 AC

11

10

14

6SL3210-1PH21-4❒L0

15

15

19

6SL3210-1PH22-0❒L0

18.5

20

23

6SL3210-1PH22-3❒L0

22

25

27

6SL3210-1PH22-7❒L0

30

30

35

6SL3210-1PH23-5❒L0

37

40

42

6SL3210-1PH24-2❒L0

45

50

52

6SL3210-1PH25-2❒L0

55

60

62

6SL3210-1PH26-2❒L0

75

75

80

6SL3210-1PH28-0❒L0

90

100

100

6SL3210-1PH31-0❒L0

110

100

115

6SL3210-1PH31-2❒L0

132

125

142

6SL3210-1PH31-4❒L0

Heat sink variant

 

 

             ↑

 

Standard

 

 

             0

 

Push Through

 

 

             1

 

Integrated line filter

 

 

                               ↑

                               ↑

Without

(for IT systems)

 

                               U

                               U

Class A

(for TN systems)

 

                               A

                               A

Class B

(for TN systems)

 

Integrated line filter not available, as external option only


 

6SL3210-1PE21-1UL0 
西门子产品订货号:6SL32101PE211UL0

西门子产品价格:168  RMB

西门子产品净重:1.100 Kg

西门子产品承诺:质保一年,原装*

西门子产品尺寸:270.00 x 225.00 x 85.00

 

西门子s7-200PLC模拟量数据格式与寻址

 

由于S7-200的模拟量输出模块都需要占占两个输出通道。即使*个模块只有一个输出AQW0,第二个模块的输出地址也应从AQW4开始寻址(AQW2被*个模块占用),依此类推。所以自然不会有输出了。

在S7-200中,单极性模拟量输入/输出信号的数值范围是 0 - 32000;双极性模拟量信号的数值范围是 -32000-+32000。

格式:

输入:AIW[起始字节地址]——如AIW6 
输出:AQW[起始字节地址]——如AQW0 
每个模拟量输入模块,按模块的先后顺序和输入通道数目,以固定的递增顺序向后排地址。 例如: AIW0、AIW2、AIW4、AIW6、AIW8等。

 对于EM231 RTD(热电阻)两通道输入模块,不再占用空的通道,后面的模拟量输入点是紧接着排地址的。温度模拟量输入模块(EM231 TC、EM231 RTD)也按照上述规律寻址,但是所读取的数据是温度测量值的10倍(摄氏或华氏温度)。如520相当于52.0度。

 注意:如果没有把握,可以在线检测到模块的起始地址,方法是:STEP 7-Micro/WIN中的菜单“PLC > Information”里在线读到。

关于Siemens S7-200的模拟量模块,有2个大家(尤其是初学者)需要注意的:

1、关于地址,其实S7-200的地址很简单,跟相对位置有关,每个模拟量输入模块,按模块的先后顺序地址为固定的,顺序向后排。可以通过编程软件information菜单来在线查看;说需要注意的就是地址都是偶数,比如AIW0 AIW2 ,没有AIW1之类的,输出地址也需要注意,比如EM235虽然只有1个通道输出,但是占用2个地址,下一个模块必须隔个地址输出,比如有CPU旁扩展2个相连的EM235,那么模拟量输出地址分别为AQW0和AQW4;

2、关于拨码开关,不同的拨码开关对应不同的测量方法,物理量的性质等等,这里zui要注意的是,拨码开关必须断电后重新上电才有效。而且需要注意的是拨码开关同时对所有通道有效。

 


免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,智能制造网对此不承担任何保证责任。

在线询价

 

广州鸿懿电气设备有限公司

型:
代理商
联系人:
王勇

联系我时,请说明是在智能制造网上看到的,谢谢

商家概况

主营产品:
西门子PLC,电线电缆,电机,变频器
公司性质:
代理商

该商家其它产品

西门子CPU1512C-1 PN处理器

西门子CPU1512C-1...

摘要:西门子CPU1512C-1PN处理器C [详细]
西门子CPU1511-1 PN参数

西门子CPU1511-1 ...

摘要:西门子CPU1511-1PN参数CPU1 [详细]
西门子CPU1511C-1 PN处理器

西门子CPU1511C-1...

摘要:西门子CPU1511C-1PN处理器C [详细]
西门子CPU1511-1 PN处理器

西门子CPU1511-1 ...

摘要:西门子CPU1511-1PN处理器CP [详细]
西门子CPU1513-1 PN处理器

西门子CPU1513-1 ...

摘要:西门子CPU1513-1PN处理器CP [详细]
西门子CPU1515-2 PN处理器

西门子CPU1515-2 ...

摘要:西门子CPU1515-2PN处理器CP [详细]
西门子CPU1516-3 PN/DP处理器

西门子CPU1516-3 ...

摘要:西门子CPU1516-3PN/DP处理 [详细]
西门子CPU1517-3 PN/DP处理器

西门子CPU1517-3 ...

摘要:西门子CPU1517-3PN/DP处理 [详细]

其它商家同类产品


新手指南
了解智能制造卖家注册买家注册操作指南手机智能在线
旗下子站
智能控制机器人物联网3D打印
站点导航
找资讯找公司找产品找展会品牌商城
本站服务
会员服务企业建站广告服务SEO优化